Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [WITHDRAWN]

DIN EN 55016-1-5:2013-06

VDE 0876-16-1-5:2013-06

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Specifications and validation procedures for CALTS and REFTS from 30 MHz to 1 000 MHz (CISPR 16-1-5:2003 + A1:2012); German version EN 55016-1-5:2004 + A1:2012

German title
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 1-5: Geräte und Einrichtungen zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Festlegungen und Eignungsprüfverfahren für Kalibrier- und Referenz-Messplätze für den Frequenzbereich von 30 MHz bis 1 000 MHz (CISPR 16-1-5:2003 + A1:2012); Deutsche Fassung EN 55016-1-5:2004 + A1:2012
Publication date
2013-06
Original language
German
Pages
59

110.24 EUR VAT included

103.03 EUR VAT excluded

Format and language options

Shipment (3-5 working days) 1
  • 110.24 EUR

Monitor with the Standards Ticker

1

 Attention: Document withdrawn!

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2013-06
Original language
German
Pages
59

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This standard contains the German version of the European Standard EN 55016-1-5:2010 and its Amendment A1:2012 and is identical to International Standard IEC/CISPR 16-1-5 (2003 edition) and its Amendment A1:2012. It specifies requirements for test sites used to perform antenna calibrations in the frequency range 30 kHz to 1 GHz. The purpose is to demonstrate - with the help of the standard - the corresponding validation of the test site. The EMC product committees and users of measurements of electromagnetic disturbances are recommended to observe the corresponding specifications of standard series IEC/CISPR 16 or EN 55016 for measuring equipment, measuring methods as well as measurement uncertainty for their specifications for measurement of high-frequency disturbances (radio disturbances). A test site which is suitable for calibration of antennas and which is called an antenna calibration test site in this standard is intended to provide a suitable environment for calibration of the free-space antenna factor. In this standard it is assumed that the calibration is carried out over a reflecting plane with the limitation to the horizontal polarization. Therefore the antenna calibration test site shall fulfil certain requirements concerning its site attenuation to be appropriate for the calibration of antennas. These requirements and the corresponding tolerances are specified in this standard and the validation procedure to be applied for antenna calibration test sites is described. The site attenuation is measured using tuned dipoles or broadband antennas. Furthermore, information that shall be contained in an acceptance certificate is summarized. Annex A provides a guideline for the set-up of an antenna calibration test site meeting the validation criteria specified in this standard. Amendment A1 serves for the introduction of the reference test site procedure as an alternative procedure for the validation of antenna calibration test sites. With this procedure the test site to be validated is now measured with broad band antennas and the deviation of the site attenuation with regard to a test site serving as a reference site is determined. The test site to be validated is assumed to be suitable if the deviation of the test site attenuation meets the criterion plus/minus 4. The test set-up and the test procedure are described in the Amendment. Furthermore it deals with the determination of the possible causes if the criterion is not met. A validated antenna calibration test site can also be used as a reference test site for the suitability test of test sites in accordance with CISPR 16-1-4, EN 550-1-4 or DIN EN 55016-1-4 (VDE 0876-16-1-4) if it meets several additional requirements. These additional requirements and design criteria are also specified in this standard. The responsible committee is UK 767.4 "Geräte und Verfahren zum Messen von elektromagnetischen Aussendungen" ("Apparatus and methods for measurement of electromagnetic emissions") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.