Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [WITHDRAWN]

DIN EN 60601-2-1:2016-08

VDE 0750-2-1:2016-08

Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV (IEC 60601-2-1:2009 + A1:2014); German version EN 60601-2-1:2015

German title
Medizinische elektrische Geräte - Teil 2-1: Besondere Festlegungen für die Sicherheit einschließlich der wesentlichen Leistungsmerkmale von Elektronenbeschleunigern im Bereich von 1 MeV bis 50 MeV (IEC 60601-2-1:2009 + A1:2014); Deutsche Fassung EN 60601-2-1:2015
Publication date
2016-08
Original language
German
Pages
77

132.55 EUR VAT included

123.88 EUR VAT excluded

Format and language options

Shipment (3-5 working days) 1
  • 132.55 EUR

Monitor with the Standards Ticker

1

 Attention: Document withdrawn!

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2016-08
Original language
German
Pages
77

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This standard amends and supplements DIN EN 60601-1 (VDE 0750-1):2013-12. The standard applies to the basic safety and essential performance of electron accelerators in the range of 1 MeV to 50 MeV for the treatment of patients. This standard establishes requirements to be complied with by manufacturers in the design and construction of electron accelerators for use in radiotherapy. No attempt is made to define requirements for their optimum operation. The purpose of this standard is to identify those features of design that are regarded, at the present time, as essential for the safe operation of such equipment; it places limits on the degradation of equipment functions beyond which it can be presumed that a fault condition exists and where an interlock then operates to prevent continued operation of the equipment. DIN EN 60976 and IEC/TR 60977 are closely related to this standard. The standard DIN EN 60976 specifies test methods and reporting formats for performance tests for electron accelerators for use in radiation therapy with the aim of providing uniform methods for conducting such tests. The technical report IEC/TR 60977 proposes performance values measured by test methods specified in DIN EN 60976 that may be achievable with current technology. The committee responsible for this standard is NA 080-00-15 GA Gemeinschaftsausschuss NAR/DKE "Strahlentherapie" (Joint Committee NAR/DKE "Radiotherapy") of the Radiology Standards Committee (NAR) at DIN in collaboration with Deutsche Röntgengesellschaft (German Radiological Society) and the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE and in collaboration with Deutsche Gesellschaft für Nuklearmedizin e. V. (DGN) (German Society of Nuclear Medicine), Deutsche Gesellschaft für Medizinische Physik e. V. (DGMP) (German Society for Medical Physics) and Deutsche Gesellschaft für Radioonkologie e. V. (DEGRO) (German Society for Radio Oncology).

Replacement amendments

Cooperation at DIN

Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...