Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [WITHDRAWN]

DIN 6868-152:2013-06

Image quality assurance in diagnostic X-ray departments - Part 152: RöV acceptance test of X-ray installations for screen/film mammography

German title
Sicherung der Bildqualität in röntgendiagnostischen Betrieben - Teil 152: Abnahmeprüfung nach RöV an Röntgeneinrichtungen für Film-Folien-Mammographie
Publication date
2013-06
Original language
German
Pages
40

from 112.30 EUR VAT included

from 104.95 EUR VAT excluded

Format and language options

PDF download 1
  • 112.30 EUR

Shipment (3-5 working days) 1
  • 135.80 EUR

Monitor with the Standards Ticker

1

 Attention: Document withdrawn!

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2013-06
Original language
German
Pages
40
DOI
https://dx.doi.org/10.31030/1962031

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

The standard applies for the procedure of the acceptance tests in accordance with § 16 of the Röntgenverordnung (German X-ray Ordinance) (RöV) on mammography installations. It is applicable for installations with image recording by screen/ film systems. The standard does not apply for mammographic stereotactic devices and special biopsy accessories. The standard replaces the preliminary standard DIN V 6868-152:2005-02 and partly replaces the draft standard DIN 6868-152:2011-01 provided it concerns specifications on the acceptance test of X-ray installations for screen/film mammography. With respect to the preliminary standard DIN V 6868-152, the requirements for the contrast and local resolution, chest wall sided image boundary, half-value layer and the test of the X-ray tube voltage have been modified. In the new edition the test criterions entrance dose, nominal dose, focal spot diameter, dose rate, linearity, attenuation factor and smallest current time product has been waived. Measurement of the entrance dose has been replaced by measurement of the glandular dose. The standard contains image quality assuring specifications according to the German X-ray Ordinance (RöV) of 8 January 1987 in the version of the publication of 30 April 2003, requirements according to § 16 and serves in connection with the Sachverständigen-Prüfrichtlinie (QS-RL) (testing guidelines for experts) and the Qualitätssicherungsrichtlinie (QS-RL) (quality assurance guidelines) for the fulfilment of national requirements in radiation protection. The requirements of the standard correspond with those of the fourth edition of the European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis. The standard has been prepared by Working Committee NA 080-00-06 AA "Bildgebende Systeme" ("Imaging systems") of the Radiology Standards Committee (NAR).

Content
ICS
11.040.50
DOI
https://dx.doi.org/10.31030/1962031
Replacement amendments

This document replaces DIN V 6868-152:2005-02 .

This document has been replaced by: DIN 6868-152:2022-01 .

Cooperation at DIN