Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Technical rule [WITHDRAWN]

DIN VDE 0100 Beiblatt 5:2017-10

VDE 0100 Beiblatt 5:2017-10

Low-voltage electrical installation - Supplement 5: Permissible lengths of cables and cords taking into consideration fault protection, protection against short circuit and voltage drop

German title
Errichten von Niederspannungsanlagen - Beiblatt 5: Maximal zulässige Längen von Kabeln und Leitungen unter Berücksichtigung des Fehlerschutzes, des Schutzes bei Kurzschluss und des Spannungsfalls
Publication date
2017-10
Original language
German
Pages
68

119.08 EUR VAT included

111.29 EUR VAT excluded

Format and language options

Shipment (3-5 working days) 1
  • 119.08 EUR

Monitor with the Standards Ticker

1

 Attention: Document withdrawn!

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2017-10
Original language
German
Pages
68

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This Supplement contains information for the planning and construction of low-voltage electrical installations; for example, the various calculation methods required for calculating the limit lengths of cables and lines and for selecting the protective devices, taking into account the various protection goals. The selection tables listed for the limit lengths of cables and lines and device parameters with specified boundary parameters support the electricians in setting up a safe low-voltage system. Compared to DIN VDE 0100 Supplement 5 (VDE 0100 Supplement 5):1995-11, the following significant changes have been made: a) the values for the limit lengths in the tables have been revised. b) the derivation of the network series impedance and the line impedances has been formulated to be generally valid, not only for outgoing and return conductors with the same cross-section, as was previously the case. c) the conductor temperature was derived at the end of the fault time. d) The impedance angles of multi-conductor cables have been adjusted. e) notes were added on: - flow chart for determining the equipment and the coordination of a circuit - important formulas for calculating short circuits in accordance with IEC 60909-0 - General equipment data - checking protection in the event of a short circuit - determining the conductor temperature at the end of the fault time - determining the limit lengths for the voltage drop - simplified approach to checking selectivity. The responsible committee is DKE/UK 221.2 "Schutz gegen thermische Auswirkungen/Sachschutz" ("Protection against thermal effects/property protection") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Replacement amendments

Cooperation at DIN

Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...