Ambient air quality - Measurement of bioaerosols - Part 1: Determination of moulds using filter sampling systems and culture-based analyses; German version CEN/TS 16115-1:2011

German title
Luftbeschaffenheit - Messen von Bioaerosolen - Teil 1: Bestimmung von Schimmelpilzen mittels Probenahme auf Filtern und kulturellem Nachweis; Deutsche Fassung CEN/TS 16115-1:2011
Publication date
2011-07
Original language
German
Pages
52
Procedure
Pre-Standard

from 103.40 EUR VAT included

from 96.64 EUR VAT excluded

Format and language options

PDF download
  • 103.40 EUR

Shipment (3-5 working days)
  • 125.00 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2011-07
Original language
German
Pages
52
Procedure
Pre-Standard
DOI
https://dx.doi.org/10.31030/1634443

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
This Technical Specification describes the measurement of moulds in ambient air in order to identify, quantify and characterize bioaerosol pollution in ambient air resulting from emissions from different sources. The method described specifies the sampling of moulds as part of the suspended particulate matter (SPM, here particles with aerodynamic diameter up to ca. 30 µm) using a filter sampling system with gelatine/polycarbonate filter combination followed by the culture-based analyses on DG18 agar. The sampling duration can be varied between 10 min to 24 h. The health effect of bioaerosols is not limited to any particle fraction, therefore, this document describes the sampling of moulds as part of the suspended particulate matter as a convention method. During filtration, a defined air quantity is sucked through a filter; airborne moulds are collected on gelatine filters resulting in a high total sampling efficiency. Polycarbonate filters are used below the gelatine filters to enhance stability. Biological sampling heads, modified with regard to ambient air measurements of particles, are developed for sampling of bioaerosols. The reason for the modification of the standardised sampling head for suspended particulate matter in ambient air was the reduction of the face velocity in order to decrease the sampling stress for moulds. Additionally, the modifications enable the use of disposable or sterilizable filter holders ensuring aseptic conditions during the handling of filter and sampling head and avoiding carry-over effects and contaminations. With the analytical methods described here, mesophilic and thermotolerant moulds are quantified by cultivation of the viable and culturable propagules on selective DG18 agar. The quantitative determination of the mould concentration is performed by counting the visually recognisable colonies following cultivation. The density of the colonies grown on the culture medium results from the number of dilution steps after suspension of the cells from the filter. Therefore, in principal several dilution steps need to be plated out.
Overview

This Technical Specification describes the measurement of moulds in ambient air in order to identify, quantify and characterize bioaerosol pollution in ambient air resulting from emissions from different sources. The method described specifies the sampling of moulds as part of the suspended particulate matter (SPM, here particles with aerodynamic diameter up to approximately 30 µm) using a filter sampling system with a gelatine/polycarbonate filter combination. The sampling duration can be varied between 10 min and 24 h. With the analytical method described here, the mesophilic and thermotolerant moulds are quantified by cultivation of the viable and culturable propagules on selective DG-18 agar. The Technical Specification DIN SPEC 91221 is a process standard and particularly deals with aspects of environmental protection focusing on microbiotic air pollution. It is directed at users from regulatory authorities, test institutes, research institutes as well as plant operators and equipment manufacturers. The Technical Specification DIN SPEC 91221 has been prepared by CEN/TC 264 "Air quality" with the intensive collaboration of German experts in WG 28 "Measurement of bioaerosols in ambient air and emissions") (secretariat and chairmanship: DIN).

Content
ICS
13.040.20
DOI
https://dx.doi.org/10.31030/1634443

Cooperation at DIN

Also available in
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...