Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Technical rule [WITHDRAWN]

DIN CEN/TS 12390-9:2017-03

DIN SPEC 91167:2017-03

Testing hardened concrete - Part 9: Freeze-thaw resistance with de-icing salts - Scaling; German version CEN/TS 12390-9:2016

German title
Prüfung von Festbeton - Teil 9: Frost- und Frost-Tausalz-Widerstand - Abwitterung; Deutsche Fassung CEN/TS 12390-9:2016
Publication date
2017-03
Original language
German
Pages
35
Procedure
Pre-Standard

from 85.20 EUR VAT included

from 79.63 EUR VAT excluded

Format and language options

PDF download 1
  • 85.20 EUR

  • 102.20 EUR

Shipment (3-5 working days) 1
  • 102.90 EUR

Monitor with the Standards Ticker

1

 Attention: Document withdrawn!

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2017-03
Original language
German
Pages
35
Procedure
Pre-Standard

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This Technical Specification describes the testing of the freeze-thaw scaling resistance of concrete both with water and with sodium chloride solution. It can be used either to compare new constituents or new concrete compositions against a constituent or a concrete composition that is known to give adequate performance in the local environment or to assess the test results against some absolute numerical values based on local experiences. Extrapolation of test results to assess different concretes, that is new constituents or new concrete compositions require an expert evaluation. There is no established correlation between the results obtained by the three test methods. All tests will clearly identify poor and good behaviour, but they differ in their assessment of marginal behaviour. The application of different acceptance limits for test results enables assessment for different degrees of exposure severity. In case of justified modifications of the test parameters, precautions might apply. Some alternative applications are described in Annex A. The standard differs from DIN CEN/TS 12390-9:2006-08 as follows: - the normative references in Clause 2 have been updated; - a specification for the measurement of the CO2 content of the air in the climatic room or chamber has been included in Clauses 5, 6 and 7 (for all test methods); - the alternative applications have been specified in detail in Annex A; - a technical specification has been included in Annex B; - the references have been updated in the bibliographies. Working Committee NA 005-07-13 AA "Zement, SpA zu Teilbereichen von CEN/TC 51 und ISO/TC 74" ("Cement, Mirror Committee of parts of CEN/TC 51 and ISO/TC 74") at DIN Standards Committee Building and Civil Engineering (NABau) is responsible for the German collaboration.

Content
ICS
91.100.30
Replacement amendments

This document has been replaced by: DIN CEN/TS 12390-9:2017-05; DIN SPEC 91167:2017-05 .