Foreword
Scope
Conformance
Optical Disk
Generating system
Receiving system
Normative references
Terms and definitions
Conventions and notations
Representation of numbers
Names
Acronyms
General description of the disk
General requirement
Environments
Test environment
Operating environment
Recorded and unrecorded disk
Environmental conditions during recording
Storage environment
Transportation
Safety requirements
Flammability
Reference measurement devices
Pick-Up Head (PUH)
PUH for measuring recorded disks
PUH for measuring unrecorded disks
Measurement conditions
Recorded and unrecorded disk
Recorded disk
Unrecorded disk
Normalized servo transfer function
Reference servo for axial tracking
Reference servo for radial tracking
Dimensional characteristics (figures 6, 7 and 8)
Overall dimensions (figure 6)
First transition area (figure 6)
Second transition area (figure 6)
Clamping Zone (figure 6)
Third transition area (figure 6)
R-Information Zone (figure 6)
Sub-divisions of the R-Information Zone
Information Zone (figure 6)
Sub-divisions of the Information zone
Lead-in Zone (figure 6)
Data Zone (figure 6)
Lead-out Zone (figure 6)
Track geometry
Channel bit length
Rim area (figure 7)
Remark on tolerances
Label
Mechanical parameters
Mass
Moment of inertia
Dynamic imbalance
Sense of rotation
Runout
Axial runout
Radial runout
Optical parameters
Recorded and unrecorded disk parameters
Index of refraction
Thickness of the transparent substrate
Angular deviation
Birefringence of the transparent substrate
Recorded disk reflectivity
Unrecorded disk parameters
Polarity of reflectivity modulation
Recording power sensitivity variation
Operational signals for recorded disk
Measurement conditions
Read conditions
Recorded disk high frequency (HF) signals
Modulated amplitude (figure 10)
Signal asymmetry
Cross-track signal
Quality of signals
Jitter
Random errors
Defects
Servo signals
Differential phase tracking error signal
Tangential push-pull signal
Groove wobble signal
Operational signals for the unrecorded disk
Measurement conditions
Recording conditions
Basic write strategy for media testing
Servo signals
Radial push-pull tracking error signal
Defects
Addressing signals
Land Pre-Pit signal
Groove wobble signal
Relation in phase between wobble and Land Pre-Pit
Operational signals for Embossed Zone
Operational signals from the Control data blocks
Measurement conditions
Read conditions
High frequency (HF) signals
Quality of signals
Servo signals
Differential phase tracking error signal
Tangential push-pull signal
Radial push-pull tracking error signal
Groove wobble signal
Operational signals from the Servo Blocks
Measurement conditions
Read conditions
Servo signals
Radial push-pull tracking error signal
Differential phase tracking signal
Addressing signals
Land Pre-Pit signal
Groove wobble signal
General
Data Frames (figure 23)
Identification Data (ID)
ID Error Detection Code
RSV
Error Detection Code
Scrambled Frames
ECC Block configuration
Recording Frames
Modulation
Physical Sectors
Suppress control of the d.c. component
Linking scheme
Structure of linking
2K-Link and 32K-Link
Lossless-Link
General description of the Information Zone
Layout of the Information Zone
Physical Sector numbering
Lead-in and Lead-out Zone
Lead-in Zone
Initial Zone
Buffer Zone 0
RW-Physical Format Information Zone
Manufacturing information
Physical format information
Reference Code Zone
Buffer Zone 1
Control Data Zone
Embossed Physical format information
Disk manufacturing information
Reserved for system use
Extra Border Zone
Lead-out Zone
General description of the Unrecorded Zone
Layout of the Unrecorded Zone
ECC Block address
ECC Block numbering
Pre-pit Data format
General description
Pre-pit block structure
Pre-pit data block configuration
Relative address
ECC Block address data configuration
Parity A and Parity B
Field ID0
Field ID1
Application code
Disk physical code
Last address of Data Recordable Zone
Version Number
Extension code
Field ID2 and ID5
OPC suggested code
OPC suggested code (Erasing power ratio)
Write Strategy code
3Ttop field
nTdtp fields (n = 4 to 11 and 14)
ε field
Tmp field
Tcl field
Field ID3 and Field ID4
Data structure of R-Information Zone
Layout of Power Calibration Area and Recording Management Area
Structure of the Power Calibration Area
Data configuration of the Recording Management Area (RMA)
Sector format of the Recording Management Area (figure 62)
The data structure of RMA
Recording Management Data (RMD)
Format1 RMD
Format1 RMD Field0
Format1 RMD Field1
Format1 RMD Field2
Format1 RMD Field3
Format1 RMD Field4
Format1 RMD Field5 to Format1 RMD Field12
Format1 RMD Field13 and Format1 RMD Field14
Format2 RMD
Format2 RMD Field0
Format2 RMD Field1
Format2 RMD Field2
Format2 RMD Field3 to Format2 RMD Field14
Format3 RMD
Format3 RMD Field0
Format3 RMD Field1
Format3 RMD Field2
Format3 RMD Field3
Format3 RMD Field4
Format3 RMD Field5 to Format3 RMD Field12
Format3 RMD Field13 and Format3 RMD Field14
Measurement of the angular deviation α (normative)
Measurement of birefringence (normative)
Principle of the measurement
Measurements conditions
Example of a measuring set-up
Measurement of the differential phase tracking error (normative)
Measuring method for the differential phase tracking error
Measurement of Δt ¯ ∕ T without time interval analyzer
Calibration of ¯ ∕
Measurement of light reflectance (normative)
Calibration method
Measuring method
Tapered cone for disk clamping (normative)
Measurement of jitter (normative)
System diagram for jitter measurement
Open loop transfer function for PLL
Slicer
Conditions for measurement
Measurement
8-to-16 Modulation with RLL (2,10) requirements (normative)
Optimum Power Control (normative)
Measurement of the groove wobble amplitude (normative)
Wobble signal (WOb)
Wobble amplitude
Measurement methods for the operational signals for an unrecorded disk (normative)
Condition of the summing amplifier in the measurement circuit
Condition of the differential amplifier in the measurement circuit
Output gain of the summing and the differential amplifiers
NBCA Code (normative)
Location of NBCA and Lead-in Zone
Writing form
Modulation method
NBCA-Code structure
NBCA-Preamble field
NBCA-Data field
NBCA-Postamble field
NBCA Error Detection Code (EDC
NBCA Error Correction Code (ECC)
NBCA-Sync-Byte (SB) and NBCA-Resync (RS)
NBCA signal specifications
NBCA signal amplitude
NBCA time period
NBCA jitter value
Logical format of information data
Border Zone (normative)
Border Zone construction
Border Zone Size
Border Zone Information
Border Zone Information Structure
Border-out and Truncated Border-out
Minimum size of Border-out and Truncated Border-out followed by Lead-out Zone
Construction of Border-out and Truncated Border-out
Write Strategy (normative)
Type 1
Type 2
Measurement method of the Land Pre-Pit signal (normative)
Transportation (informative)
General
Packaging
Temperature and humidity
Impact loads and vibrations
Erase operation and Format operation (informative)
Erase operation
Format operation