Overview
The document specifies the dimensions, steel grade and methods of use for calibration block No. 2 for calibrating ultrasonic testing equipment for the testing of steel welds. This document (EN ISO 7963:2010) of Technical Committee CEN/TC 138 "Non-destructive testing" is the adoption of the International Standard ISO 7963:2006 which has been prepared by Technical Committee ISO/TC 135 "Non-destructive testing". The responsible German Committee is Working Committee NA 062-08-23 AA "Ultraschallprüfung" ("Ultrasonic testing") of the Materials Testing Standards Committee (NMP).
Content
Content (de)
Nationales Vorwort
Änderungen
Frühere Ausgaben
Vorwort
Anerkennungsnotiz
Einleitung
Anwendungsbereich
Normative Verweisungen
Begriffe
Abmessungen
Werkstoff
Vorbereitung
Kennzeichnung
Anwendung
Kalibrierung der Zeitbasis
Kalibrierung der Zeitbasis bis zu 250 mm mit einem Senkrechtprüfkopf
Kalibrierung der Zeitbasis für 100 mm oder 125 mm mit einem Miniaturwinkelprüfkopf
Empfindlichkeitseinstellung und Überprüfung des Prüfkopfes