Standard [CURRENT]
Product information on this site:
Quick delivery via download or delivery service
All transactions are encrypted
This International Standard specifies the general rules for setting the time base range and sensitivity (that is gain adjustment) of a manually operated ultrasonic flaw detector with A-scan display in order that reproducible measurements may be made of the location and echo height of a reflector. It is applicable to techniques employing a single contact probe with either a single or twin transducers; but excludes the immersion technique and techniques employing more than one probe. The text of ISO 16811:2012 has been prepared by Technical Committee ISO/TC 135 "Non-destructive testing" of the International Organization of Standardization (ISO) and has been taken over as EN ISO 16811:2014 by Technical Committee CEN/TC 138 "Non-destructive testing", the secretariat of which is held by AFNOR (FRANCE). The responsible German body involved in its preparation is Working Committee NA 062-08-23 AA "Ultraschallprüfung" ("Ultrasonic testing") at DIN Standards Committee Materials Testing (NMP).
This document replaces DIN EN 583-2:2001-04 .