Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [WITHDRAWN]

DIN EN 61558-2-16:2010-07

VDE 0570-2-16:2010-07

Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V - Part 2-16: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units (IEC 61558-2-16:2009); German version EN 61558-2-16:2009

German title
Sicherheit von Transformatoren, Drosseln, Netzgeräten und dergleichen für Versorgungsspannungen bis 1100 V - Teil 2-16: Besondere Anforderungen und Prüfungen an Schaltnetzteilen (SMPS) und Transformatoren für Schaltnetzteile (IEC 61558-2-16:2009); Deutsche Fassung EN 61558-2-16:2009
Publication date
2010-07
Original language
German
Pages
41
Note
The publisher recommends this document in lieu of the withdrawn document DIN EN 61558-2-17:1998-07; VDE 0570-2-17:1998-07 , for which no replacement is available.

86.36 EUR VAT included

80.71 EUR VAT excluded

Format and language options

Shipment (3-5 working days) 1
  • 86.36 EUR

Monitor with the Standards Ticker

1

 Attention: Document withdrawn!

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2010-07
Original language
German
Pages
41
Note
The publisher recommends this document in lieu of the withdrawn document DIN EN 61558-2-17:1998-07; VDE 0570-2-17:1998-07 , for which no replacement is available.

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This International Standard deals with safety requirements for switch mode power supply units and transformers for switch mode power supply units. Transformers incorporating electronic circuits are also covered by this standard. This part 2-16 applies to: a) Switch mode power supply units incorporating safety isolating transformers and providing SELV, PELV or FELV a.c. or d.c. output voltage(s), or a combination thereof according to IEC 61140 and IEC 60364-4-41 for use with household and other consumer products, except for products covered by IEC 60065, IEC 61347 standard series, IEC 61204-7 and IEC 60950-1. b) Switch mode power supply units for use with household and other consumer products with a maximum output voltage not exceeding 1 000 V a.c. or 1 414 V ripple free d.c. for use with household and other consumer products, except for products described in a) and products covered by IEC 60065, IEC 61347 standard series, IEC 61204-7 and IEC 60950-1. c) This standard may also be used for transformers for use in switch mode power supply units (see Annex BB). This part covers safety requirements for: - SMPS incorporating a separating transformer for general use in accordance with part 2-1; - SMPS incorporating an isolating transformer, for general use according to part 2-4; - SMPS incorporating a safety for general use according to part 2-6; - SMPS incorporating a safety isolating transformer, for general use according to part 2-6; - SMPS incorporating an auto-transformer, for general use according to part 2-13; The requirements of the corresponding parts 2 apply for SMPS for special applications, which correspond to the other parts 2 of the 61588 standard series. The requirements in this part are additional. In case of discrepancies regarding the requirements specified in these parts, the stricter requirement shall be given priority. Switch mode power supply units covered by this standard are air cooled (natural or forced) independent, stationary, portable, associated, single-phase, or polyphase, with a rated supply voltage not exceeding 1 100 V a.c. The rated supply frequency does not exceed 500 Hz, the rated internal operating frequency exceeding 500 Hz, but not exceeding 100 MHz, and the rated output not exceeding 1 kVA or 1 kW, incorporating dry-type transformers with encapsulated or non-encapsulated windings. Associated transformers for switch mode power supply units covered by Annex BB of this standard have a rated output which shall not exceed: - 25 kVA for single-phase transformers; - 40 kVA for polyphase transformers. The no-load output voltage and the rated output voltage of switch mode power supply units shall not exceed the following values: - 1 000 V a.c. or 1 415 V ripple free d.c. when separating transformers or auto-transformers are used; - 500 V a.c. or 708 V ripple free d.c. when isolating transformers are used; - 50 V a.c. or 120 V ripple free d.c. when safety isolating transformers are used. The no-load output voltage and the rated output voltage of independent switch mode power supply units shall not exceed the following values: - 50 V a.c. or 120 V ripple free d.c. when separating transformers or auto-transformers are used. This standard is also applicable to switch mode power supply units, converters and inverters without limitation of the rated output. However, such switch mode power supply units are for special applications and are subject to an agreement between the purchaser and the manufacturer. This standard may also be used as a guide for products not covered by the scope of this standard, the scope of IEC 61204-7, or the scope of the IEC 61347 standard series. The responsible Committee is K 323 "Transformatoren, Drosseln, Netzgeräte und ähnliche Produkte für Niederspannung, jedoch bis 1 100 V" ("Transformers, reactors, power supply units and similar products for low voltages up to 1 100 V") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Replacement amendments

This document has been replaced by: DIN EN 61558-2-16:2014-06; VDE 0570-2-16:2014-06 .

Cooperation at DIN

Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...