Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

DIN EN 61000-3-12:2012-06

VDE 0838-12:2012-06

Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and ≤ 75 A per phase (IEC 61000-3-12:2011); German version EN 61000-3-12:2011

German title
Elektromagnetische Verträglichkeit (EMV) - Teil 3-12: Grenzwerte - Grenzwerte für Oberschwingungsströme, verursacht von Geräten und Einrichtungen mit einem Eingangsstrom > 16A und ≤ 75A je Leiter, die zum Anschluss an öffentliche Niederspannungsnetze vorgesehen sind (IEC 61000-3-12:2011); Deutsche Fassung EN 61000-3-12:2011
Publication date
2012-06
Original language
German
Pages
33

74.04 EUR VAT included

69.20 EUR VAT excluded

Format and language options

Shipment (3-5 working days)
  • 74.04 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2012-06
Original language
German
Pages
33

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This standard contains the German version of the second edition of the European Standard EN 61000-3-12 and is identical to the second edition of the International Standard IEC 61000-3-12. It contains requirements and limits for harmonic currents produced by equipment connected to public low-voltage systems with rated current exceeding 16 A and up to and including 75 A, intended to be connected to public low-voltage distribution systems. In addition to the requirements, the corresponding measurement and simulation methods as well as - by referring to IEC 61000-3-2 - the test conditions are specified which are intended for verification that the requirements of this standard are met. It does not mean that equipment not complying with the requirements and limits of this standard cannot be connected, although in this case special arrangements with the network operator are necessary. Designs for this purpose can be found in Annex C of this standard. Professional equipment with input current ≤ 16 A per phase and that does not comply with the requirements and limits of standard IEC 61000-3-2 may be permitted to be connected to certain types of low voltage supplies, in the same way as equipment with input current > 16 A per phase and that does not comply with the requirements and limits of the present standard. With respect to the previous edition of this standard, THD and PWHD have been replaced by THC and PWHC, amongst others, and the reference to the fundamental current of the equipment has been replaced by the reference current. The limit specifications have been extended by another table (Table 5) which applies like the previous Table 4 for balanced three-phase equipment unless certain conditions formulated in the standard do not apply. Furthermore, special type test conditions for specific equipment - air conditioners and instantaneous water heaters - have been supplemented in a new Annex A. The responsible committee is DKE/UK 767.1 "Niederfrequente leitungsgeführte Störgrößen" ("Low-frequency conducted disturbance variables") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Replacement amendments

Cooperation at DIN

Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...