Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [WITHDRAWN]

DIN EN 60947-3:2012-12

VDE 0660-107:2012-12

Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units (IEC 60947-3:2008 + A1:2012); German version EN 60947-3:2009 + A1:2012

German title
Niederspannungsschaltgeräte - Teil 3: Lastschalter, Trennschalter, Lasttrennschalter und Schalter-Sicherungs-Einheiten (IEC 60947-3:2008 + A1:2012); Deutsche Fassung EN 60947-3:2009 + A1:2012
Publication date
2012-12
Original language
German
Pages
63

115.04 EUR VAT included

107.51 EUR VAT excluded

Format and language options

Shipment (3-5 working days) 1
  • 115.04 EUR

Monitor with the Standards Ticker

1

 Attention: Document withdrawn!

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2012-12
Original language
German
Pages
63

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This standard applies to switches, disconnectors, switch-disconnectors and fuse combination units to be used in distribution circuits and motor circuits of which the rated voltage does not exceed 1 000 V a.c. or 1 500 V d.c. The manufacturer shall specify the type, ratings and characteristics according to the relevant standard of any incorporated fuses. This standard does not apply to equipment falling into the scope of IEC 60947-2, IEC 60947-4-1 and IEC 60947-5-1. However, when switches and fuse-combination units falling into the scope of this standard are normally used to start, accelerate and/or stop an individual motor they shall also comply with the additional requirements given in Annex A. Annex C contains the requirements for single pole operated three pole switches. The following modifications have been made with respect to DIN EN 60947-3 (VDE 0660-107):2010-02: - terms and definitions in clause 2 have been revised and new definitions and symbols for devices, single break and double break, have been introduced; - requirements for materials and clearance and creepage distance have been deleted, IEC 60947-1 applies; - requirements for equipment for closing operation of devices in the open position have been deleted, IEC 60947-1 applies; - requirements for degrees of protection of encapsulated devices have been deleted, IEC 60947-1 applies; - requirements for limit values for operation of power-driven devices, for undervoltage relays and releases and shunt releasers have been deleted, IEC 60947-1 applies; - EMC requirements have been updated; - temperature rise test in test sequence I has been revised. The responsible committee is K 431 "Niederspannungsschaltgeräte und -kombinationen" ("Low-voltage switchgear and controlgear assemblies") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Cooperation at DIN

Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...