Dear Customers,
We will be on our Christmas break from 23 December 2025 at 1:00 p.m. and will be available again from 5 January 2026.
Please note that new registrations and requests requiring manual processing will only be handled from this date onwards.
You may, of course, place orders and access downloads online at any time.
We wish you happy holidays, a restful break, and a healthy start to the New Year!
Your DIN Media
Standard [CURRENT]
Product information on this site:
Quick delivery via download or delivery service
All transactions are encrypted
This part of the DIN EN 60332 (VDE 0482-332) series of standards specifies a test procedure for assessment of falling flaming droplets/ particles when a single vertical electrical insulated conductor or cable, or optical fibre cable, is subjected to defined fire conditions. DIN EN 60332-1-3 (VDE 0482-332-1-3) describes the use of the 1 kW flame with a gas/air mixture and is generally applied. However, the specified test method may not be applicable to single conductors, cables or lines of less than 0,5 mm2 because the conductor melts before the test is completed, or to the test of thin fiber optic cables because the cable or line breaks before the test is completed. The tests for vertical flame propagation of an insulated conductor or a cable are divided into a series of parts in the following standards: - Part 1-1 specifies the test apparatus. - Part 1-2 specifies the test method using a 1 kW pre-mixed flame. - Part 1-3 specifies the procedure for determination of flaming droplets/particles. This amendment revises the definition and positioning of the sample, as well as the positioning of the flame. The responsible committee is Subcommittee DKE/UK 411.2 "Isolierte Starkstromleitungen" ("Insulated cables, wires and flexible cords for power installation") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.
This document replaces DIN EN 60332-1-3:2005-06; VDE 0482-332-1-3:2005-06 .