VDE 0115-320-2:2013-07

Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV; German version EN 50152-2:2012

German title
Bahnanwendungen - Ortsfeste Anlagen - Besondere Anforderungen an Wechselstrom-Schalteinrichtungen - Teil 2: Trennschalter, Erdungsschalter und Lastschalter mit einer Nennspannung größer als 1 kV; Deutsche Fassung EN 50152-2:2012
Publication date
2013-07
Original language
German
Pages
20

52.28 EUR VAT included

48.86 EUR VAT excluded

Format and language options

Shipment (3-5 working days)
  • 52.28 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2013-07
Original language
German
Pages
20

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This European Standard is applicable to single-pole and two-pole alternating current (a.c.) disconnectors, earthing switches and switches which are designed for indoor or outdoor fixed installations in tractions systems, and operated with an a.c. line voltage and frequency as specified in EN 50163. EN 50163 specifies the a.c. traction systems 15 kV 16,7 Hz and 25 kV 50 Hz. As rails of a.c. traction systems are connected to earth and included in the return current path all phase to earth voltages will be within the tolerances as specified in EN 50163. Nevertheless phase to phase voltages are sometimes higher, for example in autotransformer systems. The two poles of a switch can be connected in series to provide secure isolation (that is, two breaks in series). The responsible committee is DKE/UK 351.2 "Ortsfeste Anlagen" ("Fixed installations") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.