Stationary source emissions - Determination of low range mass concentration of dust - Part 2: Quality assurance of automated measuring systems; German version EN 13284-2:2017

German title
Emissionen aus stationären Quellen - Ermittlung der Staubmassenkonzentration bei geringen Staubkonzentrationen - Teil 2: Qualitätssicherung für automatische Messeinrichtungen; Deutsche Fassung EN 13284-2:2017
Publication date
2018-02
Original language
German
Pages
36

from 106.30 EUR VAT included

from 99.35 EUR VAT excluded

Format and language options

PDF download
  • 106.30 EUR

  • 132.90 EUR

Shipment (3-5 working days)
  • 128.50 EUR

  • 161.00 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2018-02
Original language
German
Pages
36
DOI
https://dx.doi.org/10.31030/2666119

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
This European Standard specifies specific requirements for the calibration and validation (QAL2), the ongoing quality assurance during operation (QAL3) and the annual surveillance test (AST) of automated measuring systems (AMS) used for monitoring dust emissions from stationary sources to demonstrate compliance with emission limit values below 50 mg/m3 at standard conditions. It specifically deals with measurements in wet gases and at low concentration. This document is derived from EN 14181 and is only applicable in conjunction with EN 14181. This document is applicable by direct correlation with the standard reference method (SRM) described in EN 13284-1.
Overview

This European Standard specifies the standard reference method (SRM) for the measurement of low dust concentration in ducted gaseous streams in the concentrations below 50 mg/m3 at standard conditions. This method is primarily developed and validated for gaseous streams emitted by waste incinerators. More generally, it can be applied to gases emitted from other stationary sources, and to higher concentrations. If the gases contain unstable, reactive or semi-volatile substances, the measurement depends on the sampling and filter treatment conditions. This method has been validated in field tests with special emphasis to dust concentrations around 5 mg/m3. The results of the field tests are presented in Annex A. The revised version of EN 13284-2:2004 contains corrections and adaptations to more recent standards. These include in particular: - The test criteria for QAL1 have been deleted from the scope of application, as the minimum requirements for dust measuring devices are specified in EN 15267-3. Clause 5 of EN 13284-2:2004 has been deleted accordingly. - a clause on symbols and abbreviations has been added. - Clause 6 has been adapted to the structure of Clause 6 of EN 14181:2014. - details on the functional test of dust measuring devices have been added. - the decision criteria for reducing the number of comparison measurements have been changed - a clause on the treatment of SRM readings below the limit of quantification has been added. - the clause on semi-volatile substances has been revised. Requirements for the sampling temperature of the SRM have been added. - requirements for the use of different measurement ranges have been added. - the valid calibration range may be extended to 50 % of the emission limit value for the daily average value if the existence of a linear calibration function has been demonstrated and the determined coefficient of determination is at least 0,80. - if the variability test is not passed due to the influence of semi-volatile components, other conventions for the SRM temperature according to EN 13284-1:2017, Annex H may be used. This shall be stated in the calibration report. - the conditions for reducing the number of comparison measurements have been clarified. - an informative annex on the configuration of extractive dust measuring devices has been added. - an informative annex on procedures for extending the calibration range by changing the dust concentration has been added. - the symbols of the quadratic regression have been adapted to the notation of EN 14181. - an informative annex on the configuration of AMS at mass concentrations below the limit of quantification of the SRM has been added. - an informative annex on significant technical changes has been added. This European Standard is intended in particular for testing laboratories using standard reference methods within the scope of periodic measurements, manufacturers of appropriate measuring equipment, plant operators and regulatory authorities. This European Standard deals in particular with environmental protection and quality control aspects of emission monitoring. Committee NA 134-04-01-09 UA "Staubmessung in strömenden Gasen" ("Dust measurement in flowing gases") at DIN is responsible for this standard.