DIN 42600-8:2013-10

Instrument transformers for 50 Hz, Uₘ 0,72 kV to 52 kV -Part 8: Current Transformers (support-type-insulators) Uₘ = 12 kV and Uₘ = 24 kV - Narrow design, main dimensions, indoor type

German title
Messwandler für 50 Hz, Uₘ 0,72 kV bis 52 kV - Teil 8: Stützer-Stromwandler Uₘ = 12 kV und Uₘ = 24 kV - Schmale Bauform, Hauptmaße, Innenraumausführung
Publication date
2013-10
Original language
German
Pages
5

from 42.10 EUR VAT included

from 39.35 EUR VAT excluded

Format and language options

PDF download
  • 42.10 EUR

Shipment (3-5 working days)
  • 51.00 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2013-10
Original language
German
Pages
5
DOI
https://dx.doi.org/10.31030/1937494

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

The DIN 42600 series "Instrument transformers for 50 Hz, Um 0,72 kV to 52 kV" is applicable for the designs and dimensions of instrument transformers for air-insulated indoor installations with maximum equipment voltage from 0,72 kV to 52 kV and consists of the following parts: - Part 1: Basic requirements - Part 2: Current transformers Um = 0,72 kV and Um = 1,2 kV - Main dimensions - Part 3: Voltage transformers Um 12 kV to 36 kV - Large design, main dimensions, indoor type - Part 4: Current Transformers (support-type-insulator) Um = 12 kV - Small design, main dimensions, indoor type - Part 5: Current Transformers (support-type-insulator) Um 12 kV to 36 kV - Large design, main dimensions, indoor type - Part 7: Voltage Transformers Um to 12 kV - Small design, main dimensions, indoor type - Part 8: Current Transformers (support-type-insulators) Um = 12 kV and Um = 24 kV - Narrow design, main dimensions, indoor type - Part 9: Voltage Transformers Um = 12 kV and Um = 24 kV - Narrow design, main dimensions, indoor type. This standard is applicable for instrument transformers for air-insulated indoor installations with maximum equipment voltage from 0,72 kV to 52 kV. Instrument transformers for Um = 3,6 kV and Um = 7,2 kV are preferably manufactured for the design for Um = 12 kV. For instrument transformers Um = 52 kV there exist no special specifications for the design; for this purpose only the general statements of this standard apply. It shall be applied analogously for transformers for metal-enclosed installations as well as for transformers for outdoor installations of the same voltage levels, provided no other specifications have been made. Part 2: Current transformers Um = 0,72 kV and Um = 1,2 kV - Main dimensions This standard is applicable for current transformers for air-insulated indoor installations with maximum equipment voltage 0,72 kV to 1,2 kV. This standard shall be used in conjunction with DIN 42600-1. Part 3: Voltage transformers Um 12 kV to 36 kV - Large design, main dimensions, indoor type This standard is applicable for voltage transformers for air-insulated indoor installations with maximum equipment voltage from 12 kV to 36 kV - Large design. This standard shall be used in conjunction with DIN 42600-1. Part 4: Current Transformers (support-type-insulator) Um = 12 kV - Small design, main dimensions, indoor type This standard is applicable for current transformers for air-insulated indoor installations with maximum equipment voltage 12 kV - Small design. This standard shall be used in conjunction with DIN 42600-1. Part 5: Current Transformers (support-type-insulator) Um 12 kV to 36 kV - Large design, main dimensions, indoor type This standard is applicable for current transformers for air-insulated indoor installations with maximum equipment voltage 12 kV to 36 kV - Large design. This standard shall be used in conjunction with DIN 42600-1. Part 7: Voltage Transformers Um to 12 kV - Small design, main dimensions, indoor type This standard is applicable for voltage transformers for air-insulated indoor installations with maximum equipment voltage 12 kV - Narrow design. This standard shall be used in conjunction with DIN 42600-1. Part 8: Current Transformers (support-type-insulators) Um = 12 kV and Um = 24 kV - Narrow design, main dimensions, indoor type This standard is applicable for current transformers for air-insulated indoor installations with maximum equipment voltage from 12 kV to 24 kV - Narrow design. This standard shall be used in conjunction with DIN 42600-1. Part 9: Voltage Transformers Um = 12 kV and Um = 24 kV - Narrow design, main dimensions, indoor type This standard is applicable for voltage transformers for air-insulated indoor installations with maximum equipment voltage from 12 kV to 24 kV - Narrow design. The responsible committee is K 471 "Messwandler" ("Instrument transformers") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

ICS
17.220.20
DOI
https://dx.doi.org/10.31030/1937494
Replacement amendments

This document replaces DIN 42600-8:1983-05 .