ASTM F 2371:2016

Standard Test Method for Measuring the Heat Removal Rate of Personal Cooling Systems Using a Sweating Heated Manikin

Publication date
2016 reapproved: 2024
Original language
English
Pages
4

from 65.30 EUR VAT included

from 61.03 EUR VAT excluded

Format and language options

PDF download
  • 65.30 EUR

  • 78.40 EUR

Shipment (3-5 working days)
  • 72.60 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2016 reapproved: 2024
Original language
English
Pages
4
DOI
https://dx.doi.org/10.1520/F2371-16R24

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 This test method uses a sweating manikin in an environmental chamber to measure the heat removal rate and cooling duration provided by a personal cooling garment worn with a base ensemble. 2 1.1.1 The use of a sweating heated manikin is essential because of the potentially large amount of heat dissipation from the body associated with evaporative cooling. 1.2 The experimental values obtained for the cooling rates and cooling duration apply only to the particular PCS and additional garments worn during the test and for the environmental conditions used. 1.2.1 It is feasible that this test method will yield unrealistically high cooling rates for ambient air circulation systems since the manikin's surface stays continuously saturated during the test and the relative humidity in the chamber is relatively low; consequently the convective and evaporative heat loss rates from the body to the environment are probably higher from the manikin than they would be from a human, particularly in environments with higher levels of humidity. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.