Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

ASTM D 7597:2016

Standard Test Method for Determination of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Ethyl Methylphosphonic Acid, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid and Pinacolyl Methylphosphonic Acid in Water by Liquid Chromatography/Tandem Mass Spectrometry

Publication date
2016 reapproved: 2024
Original language
English
Pages
13

Please select

from 73.80 EUR VAT included

from 68.97 EUR VAT excluded

Purchasing options

PDF download
  • 73.80 EUR

  • 88.60 EUR

Shipment (3-5 working days)
  • 82.10 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Publication date
2016 reapproved: 2024
Original language
English
Pages
13
DOI
https://dx.doi.org/10.1520/D7597-16R24

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 This procedure covers the determination of diisopropyl methylphosphonate (DIMP), ethyl hydrogen dimethylamidophosphate (EHDMAP), ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), methylphosphonic acid (MPA) and pinacolyl methylphosphonic acid (PMPA) (referred to collectively as organophosphonates in this test method) in surface water by direct injection using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS) using electrospray ionization (ESI). These analytes are qualitatively and quantitatively determined by this method. This method adheres to single reaction monitoring (SRM) mass spectrometry. 1.2 This test method has been developed by US EPA Region 5 Chicago Regional Laboratory (CRL). 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 The detection verification level (DVL) and reporting range for the organophosphonates are listed in Table 1 . 1.4.1 The DVL is required to be at a concentration at least three times below the reporting limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 displays the signal/noise ratios at the DVLs for the organophosphonates in the ESI positive mode and Fig. 2 in the ESI negative mode. RSD (%) DIMP Pos 5 16 4 95.1 65.8 136.0 17.6 19.4 21.3 22.4 DIMP Pos 10 19 5 98.2 80.0 121.0 6.1 5.5 13.6 13.8 DIMP Pos 25 26 6 102.9 74.4 128.0 5.6 5.7 14.5 14.1 DIMP Pos 125 22 5 96.6 80.4 120.0 ...
ICS
13.060.50
DOI
https://dx.doi.org/10.1520/D7597-16R24
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...