Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

ASTM D 5128:2014

Standard Test Method for On-Line pH Measurement of Water of Low Conductivity

German title
Prüfmethode für die On-line-Messung des pH-Wertes von Wasser niedriger Leitfähigkeit
Publication date
2014 reapproved: 2022
Original language
English
Pages
11

from 81.30 EUR VAT included

from 75.98 EUR VAT excluded

Format and language options

PDF download
  • 81.30 EUR

  • 97.60 EUR

Shipment (3-5 working days)
  • 90.40 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2014 reapproved: 2022
Original language
English
Pages
11
DOI
https://dx.doi.org/10.1520/D5128-14R22

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 This test method covers the precise on-line determination of pH in water samples of conductivity lower than 100 µS/cm (see Table 1 and Table 2 ) over the pH range of 3 to 11 (see Fig. 1 ), under field operating conditions. pH measurements of water of low conductivity are problematic for conventional pH electrodes, methods, and related measurement apparatus. TABLE 1 Calculated Conductivity and pH Values at 25°C of Low Concentrations of NaOH in Pure Water A Note 1 - This table tabulates the theoretical conductivity and pH values of low levels of NaOH in pure water as calculated from available thermodynamic data. Note 2 - To illustrate the high sensitivity of the sample pH at these low concentrations to contaminants, the last column lists errors that would result if the sample were contaminated with an additional 1 mg/L through sample or equipment handling errors. [...] A Data courtesy of Ref (1) . B This data developed from algorithms originally published in Ref (2) . B The boldface numbers in parentheses refer to a list of references at the end of this standard. TABLE 2 Calculated Conductivity and pH Values at 25°C of Low Concentrations of HCl in Pure Water A Note 1 - This table tabulates the theoretical conductivity and pH values of low levels of HCl in pure water as calculated from available thermodynamic data Note 2 - To illustrate the high sensitivity of the sample pH at these low concentrations to contaminants, the last column lists errors that would result if the sample were contaminated with an additional 1 mg/L through sample or equipment handling errors.[...] A Data courtesy of Ref (1) . This data developed from algorithms originally published in Ref (2) . FIG. 1 Restrictions Imposed by the Conductivity pH Relationship 1.2 This test method includes the procedures and equipment required for the continuous pH measurement of low conductivity water sample streams including the requirements for the control of sample stream pressure, flow rate, and temperature. For off-line pH measurements in low conductivity samples, refer to Test Method D5464. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ICS
71.040.50
DOI
https://dx.doi.org/10.1520/D5128-14R22
Loading recommended items...
Loading recommended items...
Loading recommended items...