Short description
1.1 This test method covers the determination of the visual measurement of the color of maleic anhydride melt before and after prolonged heating under specified conditions of time and temperature. Color values are expressed in terms of platinum-cobalt standards. 1.2 This test method covers the range 0 to 100 color standard numbers. 1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29 . 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Sections 7 , 10.2.1 , and 10.4.2 . 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.