ASTM D 2216:2019

Standard Test Methods for Laboratory Determination of Water (Moisture) Content of Soil and Rock by Mass

German title
Prüfung der Feuchte von Boden, Fels und Mischungen von Boden und Zuschlagstoffen im Labor
Publication date
2019
Original language
English
Pages
7

from 73.80 EUR VAT included

from 68.97 EUR VAT excluded

Format and language options

PDF download
  • 73.80 EUR

  • 88.60 EUR

Shipment (3-5 working days)
  • 82.10 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2019
Original language
English
Pages
7

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 These test methods cover the laboratory determination of the water (moisture) content by mass of soil, rock, and similar materials where the reduction in mass by drying is due to loss of water except as noted in 1.4 , 1.5 , and 1.8 . For simplicity, the word "material" shall refer to soil, rock or aggregate whichever is most applicable. 1.2 Some disciplines, such as soil science, need to determine water content on the basis of volume. Such determinations are beyond the scope of this test method. 1.3 The water content of a material is the ratio of the mass of water contained in the pore spaces of soil or rock material, to the solid mass of particles, expressed as a percentage. 1.4 The term "solid material" as used in geotechnical engineering is typically assumed to mean naturally occurring mineral particles of soil and rock that are not readily soluble in water. Therefore, the water content of materials containing extraneous matter (such as cement etc.) may require special treatment or a qualified definition of water content. In addition, some organic materials may be decomposed by oven drying at the standard drying temperature for this method (110±5°C). Materials containing gypsum (calcium sulfate dihydrate) or other compounds having significant amounts of hydrated water, may present a special problem as this material slowly dehydrates at the standard drying temperature (110±5°C) and at very low relative humidity, forming a compound (such as calcium sulfate hemihydrate) that is not normally present in natural materials except in some desert soils. In order to reduce the degree of dehydration of gypsum in those materials containing gypsum or to reduce decomposition in highly/fibrous organic soils, it may be desirable to dry the materials at 60°C or in a desiccator at room temperature. When a drying temperature is used which is different from the standard drying temperature as defined by this test method, the resulting water content may be different from the standard water content determined at the standard drying temperature of 110±5°C. Note 1: Test Method D2974 provides an alternate procedure for determining water content of peat materials. 1.5 Materials containing water with substantial amounts of soluble solids (such as salt in the case of marine sediments) when tested by this method will give a mass of solids that includes the previously soluble dissolved solids. These materials require special treatment to remove or account for the presence of precipitated solids in the dry mass of the specimen, or a qualified definition of water content must be used. For example, see Test Method D4542 regarding information on marine sediments. 1.6 This test standard requires several hours for proper drying of the water content specimen. Test Methods D4643 , D4944 and D4959 provide less time-consuming processes for determining water content. See Gilbert 2 for details on the background of Test Method D4643 . 1.7 Two test methods are provided in this standard. The methods differ in the significant digits reported and the size of the specimen (mass) required. The method to be used may be specified by the requesting authority; otherwise Method A shall be performed. 1.7.1 Method A- The water content by mass is recorded to the nearest 1%. For cases of dispute, Method A is the referee method. 1.7.2 Method B- The water content by mass is recorded to the nearest 0.1%. 1.8 This standard requires the drying of material in an oven. If the material being dried is contaminated with certain chemicals that may react violently or emit hazardous gases when heated, health and safety hazards may exist. Therefore, this standard should not be used in determining the water content of contaminated soils unless adequate health and safety precautions are exercised. 1.9 Units- The values stated in SI units shall be regarded as standard except the Alternative Sieve Sizes listed in Table 1 are used. No other units of measurement are included in this test method. 1.10 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026 , unless superseded by this test method. 1.10.1 This is especially important if the water content will be used to calculate other relationships such as moist mass to dry mass or vice versa, wet unit weight to dry unit weight or vice versa, and total density to dry density or vice versa. For example, if four significant digits are required in any of the above calculations, then the water content must be recorded to the nearest 0.1%. This occurs since 1 plus the water content (not in percent) will have four significant digits regardless of what the value of the water content is; that is, 1 plus 0.1/100 = 1.001, a value with four significant digits. While, if three significant digits are acceptable, then the water content can be recorded to the nearest 1%. 1.10.2 If water content data is to be used to calculate other relationships, such as moist or dry mass, wet or dry unit weight or total or dry density, then the specimen mass up to 200 g must be determined using a balance accurate to 0.01 g. 1.11 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.12 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.