Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Pre-standard [WITHDRAWN]

DIN V 18599-2:2011-12

Energy efficiency of buildings - Calculation of the net, final and primary energy demand for heating, cooling, ventilation, domestic hot water and lighting - Part 2: Net energy demand for heating and cooling of building zones

German title
Energetische Bewertung von Gebäuden - Berechnung des Nutz-, End- und Primärenergiebedarfs für Heizung, Kühlung, Lüftung, Trinkwarmwasser und Beleuchtung - Teil 2: Nutzenergiebedarf für Heizen und Kühlen von Gebäudezonen
Publication date
2011-12
Original language
German
Pages
111
Procedure
Pre-Standard

from 216.10 EUR VAT included

from 201.96 EUR VAT excluded

Format and language options

PDF download 1
  • 216.10 EUR

Shipment (3-5 working days) 1
  • 261.40 EUR

Monitor with the Standards Ticker

1

 Attention: Document withdrawn!

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2011-12
Original language
German
Pages
111
Procedure
Pre-Standard

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

DIN V 18599-2 specifies methods of calculating the energy needs for heating and cooling of the section of the building being assessed. The calculations are based on a specific zone of the building defined according to its intended use. The method of defining building zones is described in DIN V 18599-1. DIN V 18599-10 specifies boundary conditions with respect to room temperature, internal loads, lighting and air change requirements relating to usage. The procedures compiled in DIN V 18599-2 are suitable for calculating the energy need for heating of building zones which have only heating, as well as the energy needs for heating and cooling of building zones which are served by both heating and cooling systems. Particular attention is paid to determining the energy needs for heating and cooling of building zones equipped with ventilation and air conditioning systems. Methods to determine the total energy needs for heating and cooling of buildings with ventilation and air conditioning systems are described in DIN V 18599-3, which specifies the heat, cooling energy, steam and electrical energy required for operating fans for air handling and transport. To calculate the energy needs for heating and cooling, all heat sources and sinks within the building zone shall be determined and included in the balance calculations. These calculations shall also include the results of other calculations described in other parts of the DIN V 18599 series of prestandards (for example, energy gains due to artificial lighting as described in DIN V 18599-4, uncontrolled heat gains due to the heating system as described in DIN V 18599-5, etcetera). Energy needs for heating and cooling are the result of interaction between the technical characteristics of the building and the building's technical installations and equipment and of the requirements arising from the type of usage. Potential energy savings which may be achieved by modifications to the building can be estimated by determining the energy needs for heating and cooling. The energy needed for heating and, where applicable, for cooling the building zone shall be provided by heating and cooling systems. The energy used by the heating and cooling systems for supplying energy to the zone being evaluated is determined in DIN V 18599-5 to DIN V 18599-9. The values of energy need calculated according to this document are the basis for calculating the energy use of the heating and cooling systems. The method is not suitable for calculating the energy needs for heating or cooling of building zones with double glass façades. As long as no generally approved method of calculating energy characteristics of double glass façades is known, all façades of this type which are subdivided into individual storeys can be included in the calculations by being treated as sunspaces (unheated glazed annexes). DIN V 18599-2 has been approved by NA 005-56-20 GA "Gemeinschaftsarbeitsausschuss NABau/FNL/NHRS: Energetische Bewertung von Gebäuden" ("Joint Working Committee NABau/FNL/NHRS: Energy performance of buildings") and published as a prestandard.

Content
ICS
91.120.10, 91.140.10, 91.140.30
Replacement amendments

This document replaces DIN V 18599-100:2009-10 , DIN V 18599-2:2007-02 .

This document has been replaced by: DIN V 18599-2:2016-10 , DIN V 18599-2:2018-09 .

Cooperation at DIN

Also available in
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...