Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

ASTM F 3210:2022

Standard Test Method for Fatigue Testing of Total Knee Femoral Components Under Closing Conditions

Publication date
2022
Original language
English
Pages
6

from 67.40 EUR VAT included

from 62.99 EUR VAT excluded

Format and language options

PDF download
  • 67.40 EUR

Shipment (3-5 working days)
  • 75.00 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2022
Original language
English
Pages
6
DOI
https://dx.doi.org/10.1520/F3210-22E01

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 This standard applies to metallic total knee femoral components used in total knee arthroplasty (TKA). Femoral components made of nonmetallic materials (for example, ceramic, polymer) could possibly be evaluated using this test method. However, such materials may include risks of new failure mechanisms which are not considered in this test method. 1.2 The procedure described in this standard is performed on total knee femoral components for supporting determination of fatigue behavior under closing-style loading conditions. Closing-style loading refers to forces that act to reduce the femoral intercondylar depth, resulting in a tensile stress on the articular surface of the femoral condyle. (See 3.2.2 .) 1.3 Different designs can be characterized as, but not limited to, posterior cruciate ligament retaining (CR), posterior stabilizing (PS), and revision. 1.4 This standard does not address evaluation of femoral components under opening-style loading conditions which have also generated clinical failures. Under opening-style loading conditions, forces are applied to the inner contour of the femoral component in a way that the forces act to increase the intercondylar depth, or open the femoral component. 1.5 Units- The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ICS
11.040.40
DOI
https://dx.doi.org/10.1520/F3210-22E01
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...