Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

ASTM F 2778:2009

Standard Test Method for Measurement of Percent Crystallinity of Polyetheretherketone (PEEK) Polymers by Means of Specular Reflectance Fourier Transform Infrared Spectroscopy (R-FTIR)

Publication date
2009 reapproved: 2020
Original language
English
Pages
4

Please select

from 58.90 EUR VAT included

from 55.05 EUR VAT excluded

Purchasing options

PDF download
  • 58.90 EUR

Shipment (3-5 working days)
  • 65.50 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Publication date
2009 reapproved: 2020
Original language
English
Pages
4
DOI
https://dx.doi.org/10.1520/F2778-09R20

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 This test method describes the collection of absorption spectra of polyetheretherketone (PEEK) polymer in filled and unfilled grades, as supplied by a vendor, and the subsequent calculation of the percent crystallinity. The material is evaluated by infrared spectroscopy. The intensity (height) of the absorbance peaks is related to the amount of crystalline regions present in the material. 1.2 This test method can be used for PEEK consolidated forms, such as injection molded parts, as long as the samples are optically flat and smooth. 1.3 The applicability of the infrared method to industrial and medical grade PEEK materials has been demonstrated by scientific studies. Percentage of crystallinity is related to R-FTIR measurement by calibration through wide-angle x-ray scattering (WAXS) crystallinity measurements. It is anticipated that this test method, involving the peak heights near 1305 cm-1 and 1280 cm-1, will be evaluated in an Interlaboratory Study (ILS) conducted according to Test Method E691. 1.4 This test method does not suggest a desired range of crystallinity for specific applications. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ICS
83.080.20
DOI
https://dx.doi.org/10.1520/F2778-09R20
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...