Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

ASTM E 3224:2019

Standard Guide for Building Energy Performance and Improvement Evaluation in the Assessment of Property Condition

Publication date
2019
Original language
English
Pages
40

from 96.30 EUR VAT included

from 90.00 EUR VAT excluded

Format and language options

PDF download
  • 96.30 EUR

Shipment (3-5 working days)
  • 107.10 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2019
Original language
English
Pages
40
DOI
https://dx.doi.org/10.1520/E3224-19

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 Purpose- The purpose of this guide is to define a commercially useful standard in the United States of America for incorporating building energy performance into an assessment of existing property condition, and specifically into a property condition assessment (PCA) on a building involved in a commercial real estate transaction . The guide is intended to provide a methodology for the user to identify building energy under-performance compared to peer buildings. If the building is under-performing compared to its peers , a methodology is provided to identify potential energy performance improvements and provide a probable cost for such improvements. The guide may be used independently or as a voluntary supplement to ASTM Guide E2018 PCA . Utilization of this guide and incorporating it into a PCA is voluntary. If the property owner is unwilling or unable to provide building energy consumption information and it is not possible to develop a reasonable estimate of building energy consumption , the methodology defined by this guide cannot be performed. 1.2 Building Energy Performance and Improvement Evaluation (BEPIE)- the process as described in this guide by which a person collects, analyzes and reports on a building's energy consumption , compares it to peer buildings and determines if the building is under-performing . If the building is under-performing , potential major improvements ( energy efficiency measures, EEMs ) that may reduce building energy consumption to achieve parity with peer buildings are identified and a probable cost is provided. Building energy performance as defined by this guide involves the collection of annual whole building energy consumption for heating, cooling, ventilation, lighting, and other related energy-consuming end-uses . Building energy consumption , for example, includes total electricity used at the building; purchased or delivered steam, hot water, or chilled water to the building; natural gas, fuel oil, propane, biomass, or any other matter consumed as fuel at the building. Annual whole building energy consumption in kBTU/yr is weather- normalized and converted to energy use intensity ( EUI , kBTU/SF-yr), and then benchmarked against weather- normalized energy consumption in peer buildings. If the building consumes more energy than peer buildings, it is assumed to be under-performing . For under-performing buildings, the methodology provided in this guide identifies potential energy improvements and associated costs that may be able to bring the building to parity with peers . If electricity is generated on site from renewable/alternative energy systems (for example, solar photovoltaic systems, wind energy generator technology, fuel cells, or microturbines), the electricity produced is considered energy savings and is netted against building energy requirements with the purpose of reducing building EUI . The assessment conducted for the BEPIE may be a Screening Assessment (SA) that might be conducted in due diligence prior to building acquisition, or a More Comprehensive Assessment (MCA) that might be conducted by the owner of a building who may have had an SA conducted prior to acquiring the building. A BEPIE as performed according to this guide is building- and site-specific. For multifamily type property, the BEPIE is property-specific where a property may include multiple buildings. For such cases, data from the multiple buildings are aggregated prior to analysis. 1.3 Objectives- Objectives in the development of this guide are to: (1) define a commercially useful guide for incorporating building energy performance into the assessment of existing property condition as part of due diligence associated with real estate transactions conducted pre-acquisition, post-acquisition or independent of an acquisition; (2) identify buildings that consume more energy than their peers , that is, are under-performing relative to peers ; (3) identify how under-performing buildings might be improved and provide a probable cost to bring under-performing buildings to parity with peers ; (4) define a commercially useful and reliable guide for conducting a building energy performance and improvement evaluation ; (5) facilitate consistency in conducting and reporting of building energy performance and the evaluation of measures that may improve energy performance ; (6) provide a process for conducting a BEPIE that is technically sound, consistent, transparent, practical and reasonable; and (7) provide criterion for identifying what constitutes a building being considered an energy under-performer compared to its peers . 1.4 Documentation- The scope of this guide includes data collection, compilation, analysis and reporting. All sources, records and resources relied upon in the BEPIE assessment should to be documented. 1.5 Considerations Outside the Scope- The use of this guide is limited to the conduct of a BEPIE as defined by this guide. While this information may be used in assessing building valuation or for other reasons, any such use is solely between the user and the Consultant and beyond the scope of this guide. 1.6 Organization of the Guide- BEPIE has 14 sections and 12 appendices. The appendices are included for informational purposes only and are provided for guidance in implementing this guide. Section 1 Describes the scope of the guide. Section 2 Identifies referenced documents. Section 3 Provides terminology pertinent to the guide. Section 4 Discusses the significance and use of the guide. Section 5 Discusses the relationship between this guide and ASTM E2018 , ASTM E2797 and ASHRAE 211. Section 6 Describes the user's responsibilities under this guide. Section 7 Describes the data collection needs for this guide. Section 8 Describes the building energy performance and improvement evaluation process. Section 9 Describes the benchmarking process. Section 10 Describes the process for conducting a screening assessment. ...
ICS
91.120.10
DOI
https://dx.doi.org/10.1520/E3224-19
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...