ASTM E 2033/E 2033M:2024

Standard Practice for Radiographic Examination Using Computed Radiography (Photostimulable Luminescence Method)

Publication date
2024
Original language
English
Pages
13

Please select

from 73.80 EUR VAT included

from 68.97 EUR VAT excluded

Purchasing options

PDF download
  • 73.80 EUR

  • 88.60 EUR

Shipment (3-5 working days)
  • 82.10 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Publication date
2024
Original language
English
Pages
13
DOI
https://dx.doi.org/10.1520/E2033_E2033M-24

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 This practice covers the minimum requirements for computed radiographic (CR) examination for metallic and nonmetallic materials using X-ray or gamma radiation. 1.2 Applicability- The requirements in this practice are intended to control the quality of computed radiographic examinations and are not intended to establish acceptance criteria for parts or materials. 1.3 Basis of Application- The requirements of this practice, Practice E2445 , and E2446 shall be used together. The requirements of Practice E2445 will provide the baseline performance evaluation and long term stability test procedures for the CR system. Practice E2446 CR performance levels are recommended in Table 1 . The user of the CR system shall establish a written procedure that addresses the specific requirements and tests to be used in their application and shall be approved by the Cognizant Radiographic Level 3 before examination of production hardware. The items that shall be determined and addressed in the written procedure are: (a) Personnel qualification and certification. (b) Minimum effective pixel coverage appropriate to the acceptance criteria and to meet the radiographic image quality level requirements of Table 1 . (c) Additional tests in accordance with Practice E2445 deemed appropriate. (d) Organizations using a gamma source or radiation energy above 320 kV may need to modify the E2445 tests, gauges, or both. (e) Maximum allowed unsharpness when other than Table 1 . (f) The method used to provide image traceability to the part and the examination facility. 1.3.1 This practice also requires the user to perform a system qualification suitable for its intended purpose and to issue a system qualification report (see subsection 7.1 ). Additionally, the user shall develop part specific inspection procedures (see subsections 5.5 and 7.5 ). 1.4 Units- The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Where applicable, SI units are shown in brackets [xx]. 1.5 Compliance- Systems, equipment and materials that do not comply with this practice shall require a waiver from the Cognizant Engineering Organization (CEO). 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.