Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

ASTM E 161:2017

Standard Specification for Electroformed Material and Test Sieves

German title
Galvanoplastische Präzisionssiebe (mit quadratischen Öffnungen)
Publication date
2017 reapproved: 2021
Original language
English
Pages
4

Please select

from 58.90 EUR VAT included

from 55.05 EUR VAT excluded

Purchasing options

PDF download
  • 58.90 EUR

  • 70.70 EUR

Shipment (3-5 working days)
  • 65.50 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Publication date
2017 reapproved: 2021
Original language
English
Pages
4
DOI
https://dx.doi.org/10.1520/E0161-17R21

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 This specification covers the technical requirements for design and construction of electroformed sieves and sieve material. These sieves are used to perform particle-size analysis and in preparing narrowly designated particle -size fractions. They may also be used as reference standards when suitably certified. The method of certifying these sieves is included in Annex A1 . 1.2 The values stated in SI units shall be considered standard for the dimensions of the electroformed mesh openings and the size of the line width in the electroformed mesh. The values stated in inch-pound units shall be considered standard with regard to the sieve frames and to lines per unit length, as in Table 1 . The values given in parentheses are mathematical conversions that are provided for informational purposes only, and are not considered standard. (A) These nominal size openings are from the preferred number series R40/3 and R10. (Openings on apertures 32 µm and less are series R10.) These standard designations correspond to the values for test sieve apertures recommended by the International Organization for Standardization (ISO). These sizes are typical, other opening sizes are available. (B) Because of their greater durability in routine testing, sieves made close to the minimum limit are normally supplied. Sieves made close to the maximum limit may be obtained only on special order but are preferable from the standpoint of logical progression and better test completion time. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.