Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

ASTM E 1218:2021

Standard Guide for Conducting Static Toxicity Tests with Microalgae

Publication date
2021
Original language
English
Pages
14
Note
The publisher recommends this document in lieu of the withdrawn document ASTM E 1218:2004 , for which no replacement is available.

from 73.80 EUR VAT included

from 68.97 EUR VAT excluded

Format and language options

PDF download
  • 73.80 EUR

Shipment (3-5 working days)
  • 82.10 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2021
Original language
English
Pages
14
Note
The publisher recommends this document in lieu of the withdrawn document ASTM E 1218:2004 , for which no replacement is available.
DOI
https://dx.doi.org/10.1520/E1218-21

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 This guide covers procedures for obtaining laboratory data concerning the adverse effects of a test material added to growth medium on growth of certain species of freshwater and saltwater microalgae during a static exposure. These procedures will probably be useful for conducting short-term toxicity tests with other species of algae, although modifications might be necessary. Although the test duration is comparable to an acute toxicity test with aquatic animals, an algal toxicity test of short duration (72, 96 or 120 h) allows for examination of effects upon multiple generations of an algal population and thus should not be viewed as an acute toxicity test. 1.2 Other modifications of these procedures might be justified by special needs or circumstances. Although using appropriate procedures is more important than following prescribed procedures, results of tests conducted using unusual procedures are not likely to be comparable to results of many other tests. Comparison of results obtained using modified and unmodified versions of these procedures might provide useful information concerning new concepts and procedures for conducting toxicity tests with microalgae. 1.3 These procedures are applicable to many chemicals, either individually or in formulations, commercial products, or known mixtures. With appropriate modifications, these procedures can be used to conduct tests on temperature, and pH and on such materials as aqueous effluents (see Guide E1192 ), leachates, oils, particulate matter, sediments, and surface waters. Static tests might not be applicable to materials that are highly volatile, are rapidly biologically or chemically transformed in aqueous solutions, or are removed from test solutions in substantial quantities by the test vessels or organisms during the test. ( 1 ) 3 However, practical flow-through test procedures with microalgae have not been developed. 1.4 Results of tests using microalgae should usually be reported in terms of the 96-h (or other time period) IC50 (see 3.2.5 ) based on reduction in growth. In some situations, it might only be necessary to determine whether a specific concentration unacceptably affects the growth of the test species or whether the IC50 is above or below a specific concentration. 1.5 This guide is arranged as follows: Section Referenced Documents 2 Terminology 3 Summary of Guide 4 Significance and Use 5 Hazards 7 Apparatus 6 Facilities 6.1 Equipment 6.2 Test Vessels 6.3 Cleaning 6.4 Acceptability 6.5 Growth Medium 8 Test Material 9 General 9.1 Stock Solution 9.2 Test Concentration(s) 9.3 Test Organisms 10 Species 10.1 Source 10.2 Culture 10.3 Quality 10.4 Procedure 11 Experimental Design 11.1 Temperature 11.2 Illumination 11.3 Beginning the Test 11.4 Gas Exchange 11.5 Duration of Test 11.6 Biological Data 11.7 Other Measurements 11.8 Determination of Algistatic and Algicidal Effects 11.8.5 Analytical Methodology 12 Acceptability of Test 13 Calculation 14 Report 15 Keywords 16 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7 . 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ICS
07.100.20
DOI
https://dx.doi.org/10.1520/E1218-21
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...