Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

ASTM D 8445a:2022

Standard Practice for Measuring Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation Samples in a Large-scale Ventilated Enclosure

Publication date
2022
Original language
English
Pages
14

from 73.80 EUR VAT included

from 68.97 EUR VAT excluded

Format and language options

PDF download
  • 73.80 EUR

  • 88.60 EUR

Shipment (3-5 working days)
  • 82.10 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2022
Original language
English
Pages
14
DOI
https://dx.doi.org/10.1520/D8445-22A

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 This practice describes procedures for measuring the chemical emissions of volatile and semi-volatile organic compounds (VOCs and SVOCs) from spray polyurethane foam (SPF) insulation samples in a large-scale ventilated enclosure. 1.2 This practice is used to identify emission rates and factors during SPF application and up to three days following application. 1.3 This practice can be used to generate emissions data for research activities or modeled for the purpose to inform potential reentry and reoccupancy times. Potential reentry and re-occupancy times only apply to the applications that meet manufacturer guidelines and are specific to the tested formulation. 1.4 This practice describes emission testing at ambient room and substrate temperature and relative humidity conditions recognizing chemical emissions may differ at different room and substrate temperatures and relative humidity. 1.5 This practice does not address all SPF chemical emissions. This practice addresses specific chemical compounds of potential health and regulatory concern including methylene diphenyl diisocyanate (MDI), polymeric MDI (MDI oligomeric polyisocyanates mixture), flame retardants, aldehydes, and VOCs including blowing agents, and catalysts. Although specific chemicals are discussed in this practice, other chemical compounds of interest can be quantified (see target compound and generic formulation list in Appendix X1 ). Other chemical compounds used in SPF such as polyols, emulsifiers, and surfactants are not addressed by this practice. Particulate sizing and distribution are also outside the scope of this practice. 1.6 Emission rates during application are determined from air phase concentration measurements that may include particle bound chemicals. SVOC deposition to floors and ceilings is also quantified for post application modeling inputs. SVOC emission rates should only be used for modeling purposes for the duration of data collection. 1.7 Four quantification methods are described for isocyanates. The method chosen should consider safety issues such as flammability, the expected concentration, the presence of isocyanate aerosol during the phase of interest (during and post application), and if the tested SPF is high or low pressure. 1.8 This practice references similar standard practices for design, construction, performance evaluation, and use of full-scale chambers for chemical emission testing. 1.9 This practice references methods for the collection and analysis of air samples. 1.10 This practice applies to two-component open cell and closed cell SPF insulation system formulations that are processed using high-pressure or low-pressure installation processing practices and equipment. 1.11 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.12 This standard does not purport to address all of the safety concerns, if any, associated with its use. The application of SPF in a ventilated enclosure has the potential to generate a hazardous condition putting the individual responsible for spraying inserts at risk. It is the responsibility of the user of this standard to establish appropriate health and safety procedures and require appropriate certified personal protective equipment (PPE) to minimize chemical exposure. Individuals entering the ventilated enclosure during and after SPF application, for any amount of time, are expected to wear appropriate PPE. 1.13 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.14 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ICS
13.040.01, 91.100.60
DOI
https://dx.doi.org/10.1520/D8445-22A
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...