Standard Test Method for Diesel Fuel Diluent in Used Diesel Engine Oils by Gas Chromatography

Publication date
2014 reapproved: 2020
Original language
English
Pages
6
Note
The publisher recommends this document in lieu of the withdrawn document ASTM D 3524:2004 , for which no replacement is available.

Please select

from 67.40 EUR VAT included

from 62.99 EUR VAT excluded

Purchasing options

PDF download
  • 67.40 EUR

Shipment (3-5 working days)
  • 75.00 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Publication date
2014 reapproved: 2020
Original language
English
Pages
6
Note
The publisher recommends this document in lieu of the withdrawn document ASTM D 3524:2004 , for which no replacement is available.
DOI
https://dx.doi.org/10.1520/D3524-14R20

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 This test method covers the use of gas chromatography to determine the amount of diesel fuel in used engine lubricating oil. This test is limited to SAE 30 oil. The diesel fuel diluent is analyzed at concentrations up to 12 mass%. Note 1 - This test method may be applicable to higher viscosity grade oils. However, such oils were not included in the program used to develop the precision statement. 1.2 This test method is limited to gas chromatographs equipped with flame ionization detectors and temperature programmable ovens. Note 2 - The use of other detectors and instrumentation has been reported. However, the precision statement applies only when the instrumentation specified is employed. 1.3 There is some overlap of the boiling ranges of diesel fuel and SAE 30 engine oils. Moreover, the boiling range of SAE 30 oils from various sources can vary appreciably. As a result, the calibration can be altered by as much as 2%, in terms of fuel dilution. When testing unknown or mixed brands of used engine oil, it should be realized that the precision of the method may be poorer than the precision obtained when calibrating with a new oil representative of the used oil being tested. 1.4 The values stated in SI units are to be regarded as the standard. The values stated in inch-pound units are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.