Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

ASTM D 3339:2021

Standard Test Method for Acid Number of Petroleum Products by Semi-Micro Color Indicator Titration

German title
Bestimmung der Säurezahl von Mineralölerzeugnissen mittels Semimikro-Farbindikator- Titration
Publication date
2021
Original language
English
Pages
8

from 67.40 EUR VAT included

from 62.99 EUR VAT excluded

Format and language options

PDF download
  • 67.40 EUR

  • 80.90 EUR

Shipment (3-5 working days)
  • 75.00 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2021
Original language
English
Pages
8
DOI
https://dx.doi.org/10.1520/D3339-21

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 This test method covers the determination of acidic constituents in new or used petroleum products and lubricants soluble or nearly soluble in mixtures of toluene, and isopropyl alcohol. The test method is especially intended for cases in which the amount of sample available to be analyzed is too small to allow accurate analysis by Test Methods D974 or D664 . It is applicable for the determination of acids having dissociation constants in water larger than 10−9. Extremely weak acids having dissociation constants smaller than 10−9 do not interfere. Salts titrate if their hydrolysis constants are larger than 10−9. 1.2 This test method can be used to indicate relative changes in acid number that occur in an oil during use under oxidizing conditions. Although the titration is made under definite equilibrium conditions, the method does not measure an absolute acidic property that can be used to predict performance of an oil under service conditions. No general relationship between bearing corrosion and acid number is known. 1.3 Since this test method requires substantially less sample than Test Methods D974 or D664 , it provides an advantageous means of monitoring an oxidation test by changes in acid number by ( 1 ) minimizing test sample depletion for acid number analyses and thus minimizing the disturbance of the test or ( 2 ) allowing additional acid number analyses to be made while maintaining the same test sample depletion and thus providing additional data. Note 1: Some oils, such as many cutting oils, rust-proofing oils, and similar compounded oils, or excessively dark-colored oils, may be more difficult to analyze by this test method due to obscurity of the color-indicator end point. These oils can be analyzed by Test Method D664 provided sufficient sample is available. However, this situation is much less likely using Test Method D3339 than using Test Method D974 due to the use of a more highly dilute sample during the titration and due to the greater stability of the end point color change. The acid numbers obtained by Test Method D3339 may or may not be numerically the same as those obtained by Test Method D664 but they should be of the same order of magnitude. Note 2: The results obtained using this method have been found to be numerically the same as those obtained using Test Method D974 , within the precision of the two methods, for new or oxidized lubricants of the type primarily intended for hydraulic or steam turbine type service. The oxidized lubricants were obtained using the Test Method D943 oxidation test. This correlation is shown by the correlation coefficient r = 0.989 with slope s = + 1.017 and intercept y = + 0.029, calculated using the acid numbers obtained using both titration methods for the samples used for the precision statement ( 12.2 ). 2 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see Sections 7 and 9 , A1.1.4 , A2.3.1 , and A2.10.1 . 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ICS
75.080
DOI
https://dx.doi.org/10.1520/D3339-21
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...