Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

ASTM D 3270:2013

Standard Test Methods for Analysis for Fluoride Content of the Atmosphere and Plant Tissues (Semiautomated Method)

German title
Halbautomatische Bestimmung von Fluoriden in der Umgebungsluft und in Pflanzen
Publication date
2013 reapproved: 2021
Original language
English
Pages
10

Please select

from 67.40 EUR VAT included

from 62.99 EUR VAT excluded

Purchasing options

PDF download
  • 67.40 EUR

  • 80.90 EUR

Shipment (3-5 working days)
  • 75.00 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Publication date
2013 reapproved: 2021
Original language
English
Pages
10
DOI
https://dx.doi.org/10.1520/D3270-13R21

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description
1.1 These test methods describe the semiautomated procedure for the analyses of various types of samples for the purpose of determining total fluoride. Since the test methods incorporate microdistillation of the sample, they may be applied to any fluoride-containing solution where standards of identical composition have been carried through the same sample preparation procedures and have proven to provide quantitative recovery when analyzed by the semiautomated system. Conversely, the methods shall not be applied for analyses until the applicability has been demonstrated. 1.2 In normal use, the procedure can detect 0.1 µg/mL of F. The normal range of analysis is from 0.1 to 1.6 µg/mL of F. Higher concentrations can be analyzed by careful dilution of samples with reagent water. If digested samples routinely exceed 1.6 µg/mL of F, the analytical portion of the pump manifold can be modified to reduce sensitivity. However, the best procedure is to analyze a smaller aliquot of the sample. Most accurate results are obtained when the fluoride concentration falls in the middle or upper part of the calibration curve. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See 8.3, 10.2.4, and 10.2.5 for additional precautions.
ICS
13.040.20
DOI
https://dx.doi.org/10.1520/D3270-13R21
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...