Short description
1.1 This test method covers the quantitative determination of 241Am by gamma-ray spectrometry in plutonium nitrate solution samples that do not contain significant amounts of radioactive fission products or other high specific activity gamma-ray emitters. 1.2 This test method can be used to determine the 241Am in samples of plutonium metal, oxide and other solid forms, when the solid is appropriately sampled and dissolved. 1.3 The values stated in SI units are to be regarded as standard. Additionally, the non-SI units of electron volts, kiloelectron volts, and liters are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.